Effective cross-sectional area of a screw

Author: struclabExecutions: 58

※ This library was created by a member. This site is not responsible for its content.

Manage Bookmarks
Effective cross-sectional area (As) of standard metric screws
Nominal Diameter
mm
Pitch
mm
JIS B 1082
As = 0.7854 × (d – 0.9382P)²
d: Nominal diameter of the screw, mm
P: Pitch of the screw, mm

No customer feedback for this calculation yet.